Autosorb iQ - Analysis (Ar, CO2, He) - Status: Available

  • Current Status: Available
  • Training: View Topics/Sessions
  • Use Rates:
    • External Academic & Government: $3.00/Hour
    • External Affiliated Commercial/Industrial: $12.00/Hour
    • External Commercial/Industrial: $16.00/Hour
    • External International Academic: $4.00/Hour
    • Internal Standard: $2.00/Hour
  • Service: Request Service Quote. The Staff rate is $50/hour (Internal) and $55 /hour (External) in addition to the instrument rate.
  • Building: NANO (0070)
  • Room: Particle Analysis 1 (222)
  • In Cleanroom: No
  • Main Contact: Kristy Schepker
Fully automated high-resolution gas sorption analyzer possessing three sample ports (analysis station) and four sample preparation ports (outgassing station). Includes a turbo-molecular drag pump and low-pressure transducers (10 and 1 Torr) for measurement of adsorption behavior at pressures required for low surface area measurements (requires krypton) and to observe the filling of micropores.

One port is available as a chemisorption station, complete with a high-temperature (1100C) furnace coupled with fan-assisted cooling, and a digital temperature controller for precise chemisorption measurements. Includes automated gas switching, in-situ and/or separated sample preparation.

A vapor dosing option is available for both physi - and chemi- sorption analysis and features a 50C thermostatted manifold chamber. Typical vapors include water, alcohols, and aromatics which can impact material characteristics, shelf life, performance, and stability.

Also, our Autosorb iQ is integrated with a thermal conductivity detector (TCD) & cold trap option and includes electronic loop injection. TCD enables to perform temperature programmed methods TPR (temperature-programed reaction)/ TPD (temperature-programed desorption)/ TPO (temperature-programed oxidation) and pulse chemisorption analyses for use with a wide-range of gases. The included, automatic loop injector allows for easy pulse titration analyses as well as peak calibration activities. Latest Status Log EntryApr 15, 2024 - User Note: Power currently off for routine cleaning of cold trap

To select the time for your reservation, click on the calendar at the desired start time and drag to the desired end time. If you are logged in, the reservations will display the names of the reservation users. Note: If the calendar is down, the following link may also be used to create a reservation: Create Reservation (Quick Form)